DocumentCode :
3552660
Title :
Ruggedized ceramic vidicon
Author :
Ochs, S.A. ; Marschka, F.D.
Author_Institution :
Radio Corp. of America, Lancaster, Pa.
Volume :
13
fYear :
1967
fDate :
1967
Firstpage :
66
Lastpage :
66
Abstract :
A one-inch vidicon capable of withstanding sterilization treatments and severe environmental testing has been developed for space applications. The tube uses electrostatic focusing and magnetic deflection provided by photoetched deflection coils. The brazed ceramic-and-metal structure has an indium-sealed faceplate and is potted in a magnetic shield. The sterilization tests, consisting of ethylene-oxide exposure and a prolonged 135°C. dry-nitrogen bake, cause some increase in dark current and a small gain in sensitivity of the slow-scan photoconductor. The tube operates satisfactorily after undergoing high-amplitude vibration tests (e.g., 35 g at 2000 Hz and 25 g rms wide-band noise) and after 60 halfsine shock pulses having a 3000-g amplitude) 30 with 100-µ sec rise time, the other 30 with 225- µsec rise time).
Keywords :
Ceramics; Coils; Dark current; Electric shock; Electrostatics; Magnetic shielding; Noise level; Photoconductivity; Testing; Wideband;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electron Devices Meeting, 1967 International
Type :
conf
DOI :
10.1109/IEDM.1967.187827
Filename :
1474908
Link To Document :
بازگشت