• DocumentCode
    3556859
  • Title

    Imaging and detection of current conduction in dielectric films by emission microscopy

  • Author

    Chiang, Ching-Lang ; Khurana, Neeraj

  • Author_Institution
    Intel Corporation, Santa Clara, CA
  • Volume
    32
  • fYear
    1986
  • fDate
    1986
  • Firstpage
    672
  • Lastpage
    675
  • Abstract
    Current conduction in dielectric films has been studied by Emission Microscopy. By combining optical microscopy with the latest night vision technology and the computer image processing techniques, we have been able to image the extremely faint light emission accompanying current conduction in a dielectric film on silicon substrate. We have found that current flows uniformly in an undamaged capacitor initially. The capacitor then breaks down after conducting a certain amount of charge and current flow becomes constricted into the failure location. To date, we have achieved a sensitivity of 10pA/µm2uniform current conduction through a 250Å undamaged oxide. For a damaged oxide, our sensitivity is 50nA at 12V or 300nA at 5V, strongly depending on the degree of damage. The spatial resolution achieved is 0.5µm. With its unprecedented capability, Emission Microscopy can be readily used to study the physical mechanisms of dielectric conduction and pinpoint the location of gate dielectric failure.
  • Keywords
    Capacitors; Computer vision; Dielectric films; Night vision; Optical computing; Optical films; Optical imaging; Optical microscopy; Optical sensors; Stimulated emission;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices Meeting, 1986 International
  • Type

    conf

  • DOI
    10.1109/IEDM.1986.191281
  • Filename
    1486539