• DocumentCode
    3559829
  • Title

    Optimisation of a sensor for onsite detection of partial discharges in power transformers by the UHF method

  • Author

    Lopez-Roldan, J. ; Tang, T. ; Gaskin, M.

  • Author_Institution
    Powerlink Queensland, Virginia, QLD
  • Volume
    15
  • Issue
    6
  • fYear
    2008
  • fDate
    12/1/2008 12:00:00 AM
  • Firstpage
    1634
  • Lastpage
    1639
  • Abstract
    Among the different solutions which allow onsite partial discharge measurement in energized power transformers, the UHF technique is gaining general interest. In order to apply this method in existing transformers, it is considered advantageous to design a UHF sensor to be fitted inside the transformer tank. This paper describes the constraints affecting the development of such sensor and the process followed to optimize its design. During this process, different solutions for broadband UHF antennas were analysed. The selection was based on computer simulation and experimental results. Computer simulation was used to evaluate differences in radiation pattern, antenna impedance, gain and effective area. Measurements of the antenna response to different partial discharge sources in oil were performed using an oil dielectric breakdown test set in an electromagnetic shielded laboratory. A group of selected antennas were then tested in a power transformer simulating the broadband signals generated by partial discharges by injecting controlled voltage pulses in the transformer. Finally, a sensor based on a conical monopole antenna structure was built and attached to a specially designed housing to be fitted inside the transformer tank through the drain valve. This final prototype was benchmarked during a high voltage factory test of a power transformer which showed a significant partial discharge activity.
  • Keywords
    UHF antennas; UHF detectors; antenna radiation patterns; conical antennas; electromagnetic shielding; monopole antennas; partial discharge measurement; power transformer insulation; power transformer testing; transformer oil; UHF sensor optimisation; antenna impedance evaluation; broadband UHF antenna; broadband signal generation; computer simulation; conical monopole antenna; drain valve; electromagnetic shielded laboratory; high voltage factory test; oil dielectric breakdown test set; onsite partial discharge measurement; power transformer insulation; radiation pattern; voltage pulse control; Broadband antennas; Computer simulation; Constraint optimization; Optimization methods; Partial discharge measurement; Partial discharges; Petroleum; Power transformers; Sensor phenomena and characterization; Testing; Power transformers, partial discharges, UHF, detectors, antennas, design methodology;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • Conference_Location
    12/1/2008 12:00:00 AM
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2008.4712667
  • Filename
    4712667