DocumentCode
3561174
Title
A New Control Method for Power-Assisted Wheelchair Based on the Surface Myoelectric Signal
Author
Oonishi, Yuusuke ; Oh, Sehoon ; Hori, Yoichi
Author_Institution
Dept. of Electr. Eng., Univ. of Tokyo, Tokyo, Japan
Volume
57
Issue
9
fYear
2010
Firstpage
3191
Lastpage
3196
Abstract
In this paper, we design a new controller for power-assisted wheelchairs. Conventional power-assist controllers only focus on the amplification of the human input force using torque sensor. Our proposed controller does not use a torque sensor but an electromyogram sensor to estimate the driver´s intention. We also use a disturbance observer to compensate for the lack of propelling torque information since it is difficult to simply regard the myoelectric signals as propelling torque. Then, we decide assist torque by combining the filtered myoelectric signals and the estimated human torque signal calculated by the disturbance observer. Experimental results show that the proposed power-assist method realizes fast, stable, and smooth acceleration.
Keywords
electromyography; force sensors; handicapped aids; wheelchairs; disturbance observer; electromyogram sensor; power-assist controller; power-assisted wheelchair; surface myoelectric signal; torque information; torque sensor; Disturbance observer; electromyogram (EMG); power-assisting control; wheelchair;
fLanguage
English
Journal_Title
Industrial Electronics, IEEE Transactions on
Publisher
ieee
Conference_Location
6/10/2010 12:00:00 AM
ISSN
0278-0046
Type
jour
DOI
10.1109/TIE.2010.2051931
Filename
5483205
Link To Document