• DocumentCode
    3563551
  • Title

    A novel fault location algorithm uttlized in marine system with CWT

  • Author

    Jia, Ke ; Thomas, David ; Sumner, Mark

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Univ. of Nottingham, Nottingham, UK
  • Volume
    1
  • fYear
    2011
  • Firstpage
    413
  • Lastpage
    417
  • Abstract
    This paper introduces a method for fault location in a marine power system which uses the voltage and current transient information at a power supply point and the remote point beyond the fault location to estimate the fault position. The proposed algorithm was demonstrated by computer simulation in Matlab with a 6-zone marine power system which has short distribution cables and requires fast and accurate fault location. The simulation results show good accuracy when the proposed algorithm was utilized in both for a single zone and for two adjacent zones regardless the variation of fault impedances.
  • Keywords
    fault location; marine power systems; mathematics computing; 6-zone marine power system; CWT; Matlab; current transient information; fault location algorithm; power supply point; remote point; voltage transient information; Circuit faults; Fault location; Impedance; Power systems; Time frequency analysis; Transient analysis; Fault location; double-ended; impedance calculation; transient measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advanced Power System Automation and Protection (APAP), 2011 International Conference on
  • Print_ISBN
    978-1-4244-9622-8
  • Type

    conf

  • DOI
    10.1109/APAP.2011.6180437
  • Filename
    6180437