Analysis of Lead Acid battery operation based on Peukert formula
Author
Utomo, A.R. ; Husnayain, F. ; Priambodo, P.S.
Author_Institution
Dept. of Electr. Eng., Univ. Indonesia, Depok, Indonesia
fYear
2014
Firstpage
345
Lastpage
348
Abstract
The aim to keep the battery performance remains good, so the operation indicators need to be monitored at all times. Although the Peukert empirical formulation is simple and the result is a mathematical approach that is theoretically present, but these results are fundamental to the operation of the battery indicator. Value of the constants, in a narrow range, it is the most decisive indicator battery performance, especially Lead Acid. Performance parameters, such as capacity, SOC, voltage, etc. can be determined after a battery Peukert numerical values are known. Although only by modeling, computation and analysis, battery condition can be monitored, so that the performance can be properly maintained operation.
Keywords
lead acid batteries; Peukert formula; battery Peukert numerical values; battery condition; indicator battery performance; lead acid battery operation; Batteries; Conferences; Discharges (electric); Equations; Lead; Lead compounds; Mathematical model; Analysis; Battery Operation; Lead Acid Battery; Peukert Formula;
fLanguage