• DocumentCode
    3564226
  • Title

    Analysis of Lead Acid battery operation based on Peukert formula

  • Author

    Utomo, A.R. ; Husnayain, F. ; Priambodo, P.S.

  • Author_Institution
    Dept. of Electr. Eng., Univ. Indonesia, Depok, Indonesia
  • fYear
    2014
  • Firstpage
    345
  • Lastpage
    348
  • Abstract
    The aim to keep the battery performance remains good, so the operation indicators need to be monitored at all times. Although the Peukert empirical formulation is simple and the result is a mathematical approach that is theoretically present, but these results are fundamental to the operation of the battery indicator. Value of the constants, in a narrow range, it is the most decisive indicator battery performance, especially Lead Acid. Performance parameters, such as capacity, SOC, voltage, etc. can be determined after a battery Peukert numerical values are known. Although only by modeling, computation and analysis, battery condition can be monitored, so that the performance can be properly maintained operation.
  • Keywords
    lead acid batteries; Peukert formula; battery Peukert numerical values; battery condition; indicator battery performance; lead acid battery operation; Batteries; Conferences; Discharges (electric); Equations; Lead; Lead compounds; Mathematical model; Analysis; Battery Operation; Lead Acid Battery; Peukert Formula;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Engineering and Computer Science (ICEECS), 2014 International Conference on
  • Print_ISBN
    978-1-4799-8477-0
  • Type

    conf

  • DOI
    10.1109/ICEECS.2014.7045275
  • Filename
    7045275