DocumentCode :
3566220
Title :
Improving performance of single-phase SOGI-FLL under DC-offset voltage condition
Author :
Tuan Ngo ; Quan Nguyen ; Santoso, Surya
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Texas at Austin, Austin, TX, USA
fYear :
2014
Firstpage :
1537
Lastpage :
1541
Abstract :
The second-order-generalized-integrator frequency-locked loop (SOGI-FLL) is typically employed to synchronize with the grid in the single-phase grid-connected converter. The SOGI creates two orthogonal signals from an input grid voltage, and estimates the magnitude while the frequency locked-loop identifies the grid frequency. If there is a DC component in the grid voltage due to the measurement process, it degrades the accuracy of SOGI-FLL estimates. The SOGI-FLL, therefore, cannot identify accurate information of the grid voltage. This paper introduces an improved control method for the SOGI-FLL when the grid contains a DC component. The value of the DC component voltage is estimated online and totally removed from the frequency control loop. The controller, thus, responses faster and more precisely detects both the magnitude and frequency of the input voltage. Simulation results are presented to verify the theoretical analyses.
Keywords :
convertors; frequency locked loops; dc component voltage; dc-offset voltage condition; frequency control loop; grid frequency; grid voltage; measurement process; orthogonal signals; second-order-generalized-integrator frequency-locked loop; single-phase SOGI-FLL; single-phase grid-connected converter; Frequency control; Frequency estimation; Frequency locked loops; Phase locked loops; Synchronization; Voltage control; Voltage measurement; DC-offset; Frequency Locked-Loop (FLL); Second-Order-Generalized-Integrator (SOGI); grid synchronization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics Society, IECON 2014 - 40th Annual Conference of the IEEE
Type :
conf
DOI :
10.1109/IECON.2014.7048706
Filename :
7048706
Link To Document :
بازگشت