DocumentCode
3567500
Title
Circular beam scanning power system for isotope production upgrade
Author
Lambiase, Robert ; Altinbas, Zeynep
Author_Institution
Collider - Accel. Dept., Brookhaven Nat. Lab., Upton, NY, USA
fYear
2014
Firstpage
5026
Lastpage
5028
Abstract
To increase the production of medical isotopes, an upgrade to the Brookhaven Linac Isotope Producer (BLIP) facility is now being designed and constructed. Currently, the ion beam strikes the isotope producing target in a single spot. With this upgrade, the ion beam will be directed to hit the target in circular patterns, distributing the heat of collision over a bigger area on the target. The power system to create the circular patterns requires orthogonal dipole magnets with sinusoidal currents which are ninety degrees apart from each other. This paper describes the design concept for powering the magnets and the control system that produces the correct waveforms despite component variations.
Keywords
beam handling equipment; ion beams; linear accelerators; power system control; radioactive sources; BLIP; Brookhaven Linac Isotope Producer; circular beam scanning power system; ion beam; isotope production upgrade; medical isotopes production; orthogonal dipole magnets; Capacitors; Control systems; Isotopes; Magnetic circuits; Magnetic resonance; Monitoring; Power supplies; resonant circuits;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics Society, IECON 2014 - 40th Annual Conference of the IEEE
Type
conf
DOI
10.1109/IECON.2014.7049263
Filename
7049263
Link To Document