DocumentCode :
3570328
Title :
Low cycle fatigue tests on low carbon steel
Author :
Yunrong, Luo ; Qingyuan, Wang ; Bo, Yang
Author_Institution :
Coll. of Archit. & Environ., Sichuan Univ., Chengdu, China
Volume :
4
fYear :
2011
Firstpage :
741
Lastpage :
746
Abstract :
Cyclic material tests in the low cycle fatigue(LCF) regime were carried out to study the effect of frequency, strain ratio and specimen dimension on LCF life of high strength low carbon steel(cold-rolled Q235 steel). A total of 83 experiments were performed under uniaxial tension-compression loading with total strain control. The LCF behavior of the test material was found to be strong dependent on frequency and strain ratio, but weakly dependant on specimen dimension. The material displayed significant cyclic softening. The data obtained from the LCF tests were used to derive suitable Coffin-Manson parameters for the material. The results would provide reference on LCF tests and engineering application of cold-rolled Q235 steel.
Keywords :
carbon steel; cold rolling; fatigue; fatigue testing; softening; Coffin-Manson parameters; cold-rolled Q235 steel; cyclic softening; frequency effect; low carbon steel; low cycle fatigue tests; strain ratio; uniaxial tension-compression loading; Carbon; Fatigue; Materials; Softening; Steel; Strain; Strain control; frequency; low carbon steel; low cycle fatigue (LCF); specimen dimension; strain ratio;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Business Management and Electronic Information (BMEI), 2011 International Conference on
Print_ISBN :
978-1-61284-108-3
Type :
conf
DOI :
10.1109/ICBMEI.2011.5921073
Filename :
5921073
Link To Document :