DocumentCode
3570449
Title
Optimizing the luminosity in the Tevatron by independently moving the horizontal and vertical beta stars longitudinally
Author
Martens, M.A. ; Goderre, G.P.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume
1
fYear
1995
Firstpage
446
Abstract
The low beta triplet in the Tevatron is instrumented such that it is possible to move the horizontal and/or the vertical beta star in the longitudinal direction. This control over beta star allows us to minimize the longitudinal separation of horizontal and vertical beta star at each interaction region independently, thus maximizing the luminosity. Results of varying the longitudinal separation of horizontal and vertical beta star are shown and the sensitivity of the luminosity on this parameter is discussed
Keywords
particle beam focusing; proton accelerators; storage rings; synchrotrons; Tevatron; beta stars; interaction region; low beta triplet; luminosity; Contracts; Detectors; Educational institutions; Forging; Instruments; Laboratories; Lattices; Magnets; Power supplies; Protons;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.504686