DocumentCode :
357135
Title :
EMI problems and control methods in data acquisition systems
Author :
Mourougayane, K. ; Karunakaran, S.
Author_Institution :
Commun. Syst. & Projects Div., SAMEER, Chennai, India
fYear :
1999
fDate :
6-8 Dec. 1999
Firstpage :
39
Lastpage :
42
Abstract :
Data Acquisition System (DAS) involves measurement of different types of signals whose level will vary from sensitive low voltage to dangerous high voltage sharing common ground. Poor grounding and isolation between channels, between channel to earth results in false and inaccurate representation of acquired signals. Proper use and implementation of signal conditioning methods helped in eliminating problems related to ground loop and common mode voltages. The Electromagnetic interference (EMI) problems encountered in the development of Data acquisition systems and the techniques followed to control the noise will be discussed.
Keywords :
data acquisition; electromagnetic interference; interference suppression; data acquisition system; electromagnetic interference; noise control; signal conditioning; Control systems; Data acquisition; Electromagnetic interference; Electromagnetic measurements; Low voltage; Switches; Switching converters; Testing; Transducers; Uninterruptible power systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Interference and Compatibility '99. Proceedings of the International Conference on
Print_ISBN :
81-900652-0-3
Type :
conf
DOI :
10.1109/ICEMIC.1999.871593
Filename :
871593
Link To Document :
بازگشت