DocumentCode :
357149
Title :
Error analysis in surface transfer impedance measurements on shielded cables
Author :
Sakthivel, K.N. ; Das, Sisir K. ; Ganesan, R.
Author_Institution :
Centre for Electromagn., SAMEER, Chennai, India
fYear :
1999
fDate :
6-8 Dec. 1999
Firstpage :
126
Lastpage :
128
Abstract :
This paper describes, with experimental data and graphs, errors in the surface transfer impedance (STI) measurements that could resulted from different input power levels applied to the test cable. It also describes the causes of the errors due to other reasons and how they could be avoided. It concludes by justifying the appropriate input power level to be used while using this particular standard for STI measurements.
Keywords :
UHF measurement; cable testing; coaxial cables; electric impedance measurement; electromagnetic shielding; error analysis; microwave measurement; military equipment; 0.1 to 30 MHz; STI measurements; error analysis; input power level; shielded cables; surface transfer impedance measurements; test cable; Cable shielding; Cables; Conductors; Current measurement; Error analysis; Impedance measurement; Radio frequency; Surface impedance; Testing; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Interference and Compatibility '99. Proceedings of the International Conference on
Print_ISBN :