DocumentCode :
357849
Title :
Correcting OATS antenna factors for small fully anechoic chambers
Author :
Hansen, Diethard ; Ristau, Detlef ; Lilienkamp, Peter
Author_Institution :
EURO EMC SERVICE, Berikon, Switzerland
Volume :
1
fYear :
2000
fDate :
2000
Firstpage :
219
Abstract :
Antenna correction factors have been experimentally determined inside a 3 m fully anechoic chamber. In the frequency range of 30-1000 MHz deviations to the manufacturer data, taken from a 10 m OATS, of up to 5 dB have been found in the low frequency range. In the high frequency range the calibration for horizontal polarization was strongly affected, in a narrow frequency band, by the laminated, wooden turntable plate at a 0.8 m height with up to 20 dB
Keywords :
anechoic chambers (electromagnetic); antennas; calibration; conformance testing; electromagnetic wave polarisation; electromagnetic wave reflection; 0.8 m; 10 m; 3 m; 30 to 1000 MHz; HF range; LF range; OATS antenna factors correction; UHF; VHF; calibration; compliance testing; ferrite lining; frequency band; height; high frequency range; horizontal polarization; laminated wooden turntable plate; low frequency range; manufacturer data; reflection effects; small fully anechoic chambers; table top reflections; Anechoic chambers; Antenna measurements; Batteries; Calibration; Dipole antennas; Ferrites; Frequency; Open area test sites; Receiving antennas; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2000. IEEE International Symposium on
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-5677-2
Type :
conf
DOI :
10.1109/ISEMC.2000.875566
Filename :
875566
Link To Document :
بازگشت