Title
An accurate lossless current sensing approach for a DC-DC converter with online calibration
Author
Li, B.X. ; Low, K.S. ; Kang, B.Y.
Author_Institution
Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore, Singapore
fYear
2014
Firstpage
1
Lastpage
5
Abstract
Lossless inductor current sensing is preferred in the current controlled DC-DC converters to improve the power efficiency. However the sensing accuracy for the conventional lossless method is not as good as the direct current measurement with shunt resistors. In this paper, a novel online calibration method using the matched complementary filter (MCF) current sensing is proposed to overcome the poor accuracy problem in particular due to the parameter variation. The result shows that the proposed method can achieve 1% accuracy on parameter estimation and 5% accuracy on current sensing.
Keywords
DC-DC power convertors; calibration; electric current control; electric current measurement; matched filters; parameter estimation; DC-DC converter; MCF current sensing; accurate lossless current sensing approach; direct current measurement; matched complementary filter current sensing; online calibration method; parameter estimation; power efficiency; shunt resistors; Calibration; Current measurement; Inductors; Matched filters; Parameter estimation; Resistance; Sensors; Lossless current sensing; Online calibration; parameter estimation;