DocumentCode
3582276
Title
Detection of respiratory paradoxical movement via Doppler radar measurements
Author
Yee Siong Lee ; Pathirana, Pubudu N. ; Steinfort, Christopher L.
Author_Institution
Sch. of Eng., Deakin Univ., Geelong, VIC, Australia
fYear
2014
Firstpage
1
Lastpage
5
Abstract
This paper presents an evaluation of microwave Doppler radar in capturing the respiration signal from the chest and abdomen simultaneously using two radar systems. Two experiments were conducted to investigate the feasibility of using Doppler radar in measuring respiration from both chest and abdomen simultaneously. Results obtained indicate that the respiration patterns from the radar were highly correlated with the reference respiration strap readings for normal breathing scenarios and also sensitive enough in capturing the paradoxical movement between the chest and the abdomen in the professionally role played experiments.
Keywords
Doppler radar; biomedical measurement; patient diagnosis; pneumodynamics; abdomen; chest; microwave Doppler radar measurement; reference respiration strap reading; respiration measurement; respiration signal; respiratory paradoxical movement detection; Atmospheric measurements; Demodulation; Doppler radar; Frequency measurement; Particle measurements; Radar measurements; Doppler radar; Paradoxical; respiration patterns;
fLanguage
English
Publisher
ieee
Conference_Titel
Information and Automation for Sustainability (ICIAfS), 2014 7th International Conference on
Type
conf
DOI
10.1109/ICIAFS.2014.7069602
Filename
7069602
Link To Document