    Electrical strength of the vacuum gaps in case with Pt-Ba cathode

  • Author

    Zilberman, M.M. ; Kogel, M.L.

  • Author_Institution
    Special Design Office, Ryazan, Russia
  • Volume
    1
  • fYear
    2000
  • fDate
    2000
  • Abstract
    Summary form only given. The electrical strength of vacuum gaps with a Pt-Ba cathode in experimental diodes and triodes with external copper anodes was investigated. Investigations were carried out on the diodes with negative anode voltage up to 60 kV. They helped to determine that the factor to limit maximum breakdown field in the space between the anode and cathode was heating of the Pt-Ba cathode by anode current. Heating of the Pt-Ba cathode up to a work temperature of 1370 K served as a criterion of the maximum breakdown field
  • Keywords
    anodes; barium alloys; cathodes; copper; electric breakdown; electric strength; insulation testing; platinum alloys; vacuum insulation; 1370 K; 60 kV; Cu; Pt-Ba; Pt-Ba cathode; anode current; diodes; electrical strength; external copper anodes; maximum breakdown field; negative anode voltage; triodes; vacuum gaps; work temperature; Anodes; Cathodes; Computer aided software engineering; Copper; Diodes; Electric breakdown; Scanning electron microscopy; Space heating; Temperature; Voltage;