Title :
Microphonics testing of the CEBAF upgrade 7-cell cavity
Author :
Davis, G. ; Delayen, J. ; Drury, M. ; Hiatt, T. ; Hovater, C. ; Powers, T. ; Preble, J.
Author_Institution :
TJNAF, Newport News, VA, USA
fDate :
6/23/1905 12:00:00 AM
Abstract :
An upgrade cryomodule is being developed for CEBAF at Jefferson Lab. In support of this effort, vibration testing was performed on a single SRF cavity at cryogenic temperaturse in a Horizontal Test Bed. The tests included response to excitation from background vibration, swept sinusoids, high-power RF pulses, and mechanical impulses. Test procedures, apparatus, and results are presented, along with a description of planned follow-up tests
Keywords :
accelerator cavities; superconducting cavity resonators; testing; vibration measurement; 7-cell cavity; CEBAF; cryomodule; high-power RF pulses; microphonics; superconducting RF cavity; swept sinusoids; vibration testing; Frequency estimation; Frequency modulation; Instruments; Monitoring; Phase locked loops; Radio frequency; Resonance; Signal generators; Testing; Vibration measurement;
Conference_Titel :
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN :
0-7803-7191-7
DOI :
10.1109/PAC.2001.986610