Title :
The self-breakdown voltage of pseudospark switches
Author :
Xie, Zifeng ; Luo, Chengmu ; Zhao, Huiliang
Author_Institution :
Dept. of Electr. Eng., Tsinghua Univ., Beijing, China
Abstract :
In order to develop a high hold-off voltage (over 60 kV) pseudospark switch (PSS), the parameters which affect the hold-off voltage such as the working gas, the pressure, the gap distance and the hole diameter of the electrodes etc. have been studied. The experiment results show that helium is a best choice as the working gas; the hold-off voltage inverses with two gap distance of the electrodes and the diameter of the hole on the electrodes. A new type of two stage PSS which possesses a hollow intermediate electrode has been developed. The self-breakdown curve of the improved two-stage PSS is shifted to higher pressures corresponding to that of the one-stage PSS and the ordinary two-stage PSS which possesses a plane intermediate electrode. Then it can operate at higher voltages. With the same condition, the erosion caused by discharge on the electrodes can be lowered and the lifetime is prolonged
Keywords :
discharges (electric); electrodes; pulsed power switches; spark gaps; gap distance; hold-off voltage; hole diameter; hollow intermediate electrode; plane intermediate electrode; pseudospark switches; pulsed power switches; self-breakdown curve; self-breakdown voltage; working gas; Anodes; Apertures; Breakdown voltage; Cathodes; Circuit testing; Electrodes; Helium; Nitrogen; Resistors; Switches;
Conference_Titel :
Discharges and Electrical Insulation in Vacuum, 2000. Proceedings. ISDEIV. XIXth International Symposium on
Conference_Location :
Xi´an
Print_ISBN :
0-7803-5791-4
DOI :
10.1109/DEIV.2000.877315