Abstract
Experimental data on triggering of a pseudospark switch with a trigger unit based on auxiliary glow discharge are presented. Due to modifications in the trigger electric circuit, the switch is triggered starting from a voltage of 50 V at a current level of several mAmps. With a voltage of 150-200 V the delay time to triggering does not exceed 200 ns
Keywords
electrodes; glow discharges; pulsed power switches; spark gaps; 150 to 200 V; 50 V; auxiliary glow discharge; delay time; electrodes; low voltage triggering; pseudospark switch triggering; trigger electric circuit; Apertures; Cathodes; Delay effects; Electrodes; Glow discharges; Low voltage; Plasma density; Power supplies; Switches; Switching circuits;