Title :
Bench test of a residual gas ionization profile monitor (RGIPM)
Author :
Sellyey, W.C. ; Gilpatrick, J.D. ; Senior, Ralph
Author_Institution :
Los Alamos Nat. Lab., NM, USA
fDate :
6/23/1905 12:00:00 AM
Abstract :
An RGIPM has been designed, constructed and bench tested to verify that all components are functioning properly and that the desired resolution of about 50 μm rms can be achieved. This paper will describe major considerations that went into the bench test and some results
Keywords :
electromagnets; ionisation chambers; particle beam diagnostics; 50 micron; bench test; residual gas ionization profile monitor; resolution; Detectors; Electrodes; Electron beams; Ionization; Magnetic cores; Magnetic field measurement; Monitoring; System testing; US Department of Energy; Wire;
Conference_Titel :
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN :
0-7803-7191-7
DOI :
10.1109/PAC.2001.986666