Abstract :
A high-current two-section pulsed electron linear accelerator (ELA) "EPOS" has been in successful operation at "Accelerator" R&D Production Establishment, NSC KIPT, for a few years. Its main parameters are the current pulse length -4 μs, the pulse current 0.4 to 1 A, the pulse recurrence rate -150 Hz, the electron energy - up to 30 MeV. To provide a safe beam guiding, four-winding magnetic induction monitors were devised, making possible measurements of the position of the beam current center relative to the accelerator axis with an error of ±0.5 mm at the input and output of the second accelerating section. At present, the "Accelerator" specialists have developed a compact two-section ELA "KUT-20", at the output of which a similar magnetic induction monitor is installed. Below, we present the results of bench calibration of the monitor as well as the experimental results of measuring-channel operation at the "EPOS" accelerator. The possibility of determining the second moment, which characterizes the difference of the beam cross section from its axially symmetric section, is demonstrated
Keywords :
accelerator control systems; calibration; electron accelerators; electron beams; linear accelerators; particle beam diagnostics; particle beam dynamics; particle beam stability; 0 to 30 MeV; 0.4 to 1 A; 150 Hz; 4 mus; ELA; EPOS; accelerator axis; beam spatial characteristics; bench calibration; current pulse length; electron energy; high-current two-section pulsed electron linear accelerator; magnetic induction monitor measurements; measuring-channel operation; pulse current; pulse recurrence rate; safe beam guide; technological electron linear accelerators; winding magnetic induction monitors; Acceleration; Accelerator magnets; Calibration; Current measurement; Electron accelerators; Linear accelerators; Monitoring; Particle beams; Position measurement; Production;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN :
0-7803-7191-7
Type :
conf
DOI :
10.1109/PAC.2001.986672
Filename :
986672
Link To Document :
بازگشت