DocumentCode
3583542
Title
BPM system evaluation using model-independent analysis
Author
Wang, Chun-xi ; Borland, Michael ; Sajaev, Vadim ; Kim, Kwang-Je
Author_Institution
Adv. Photon Source, Argonne Nat. Lab., IL, USA
Volume
2
fYear
2001
fDate
6/23/1905 12:00:00 AM
Firstpage
1354
Abstract
An effort is underway at the Advanced Photon Source (APS) to explore the Model-Independent Analysis method on the APS storage ring. Effective methods are developed to efficiently evaluate the beam position monitors´ (BPMs´) performance and to easily identify the malfunctioning BPMs. Such a monitoring procedure can help to improve the overall reliability and performance of the BPMs, and thus benefit machine operation and physics studies. We show that the Model-Independent Analysis can resolve beam motion below the individual BPM resolution
Keywords
electron accelerators; particle beam diagnostics; storage rings; APS storage ring; Advanced Photon Source; beam position monitors; machine operation; machine physics; model-independent analysis method; monitoring procedure; reliability; Condition monitoring; History; Laboratories; Motion analysis; Motion measurement; Performance analysis; Physics; Position measurement; Statistical analysis; Storage rings;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN
0-7803-7191-7
Type
conf
DOI
10.1109/PAC.2001.986678
Filename
986678
Link To Document