DocumentCode :
3583562
Title :
An upgrade for the beam position monitoring system at the Cornell Electron Storage Ring
Author :
Palmer, M. ; Dobbins, J. ; Hartill, D. ; Strohman, C.
Author_Institution :
Cornell Univ., Ithaca, NY, USA
Volume :
2
fYear :
2001
fDate :
6/23/1905 12:00:00 AM
Firstpage :
1360
Abstract :
We describe the design and initial characterization of a fast (nanosecond time scale), high resolution (micron level) beam position monitoring system for use in the Cornell Electron Storage Ring (CESR). Beam position monitoring requirements at CESR include 1) precision orbit measurements in the interaction region and near the synchrotron x-ray beam lines, 2) monitoring of individual bunch positions during multi-bunch high energy physics (HEP) operation, 3) single pass measurements to monitor injected bunch oscillations and injection transients, and 4) operation at both HEP and injection current levels which vary by 5 orders of magnitude. The ready availability of electronic components with large bandwidth and dynamic range for the communications industry has allowed us to economically implement a system providing this range of capabilities
Keywords :
colliding beam accelerators; electron accelerators; particle beam diagnostics; storage rings; CESR; Cornell Electron Storage Ring; beam position monitoring system; bunch positions; injected bunch oscillations; injection transients; multi-bunch high energy physics operation; precision orbit measurements; single pass measurements; synchrotron X-ray beam lines; Current measurement; Electron beams; Electronic components; Energy measurement; Energy resolution; Extraterrestrial measurements; Monitoring; Position measurement; Storage rings; Synchrotrons;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN :
0-7803-7191-7
Type :
conf
DOI :
10.1109/PAC.2001.986680
Filename :
986680
Link To Document :
بازگشت