DocumentCode
3583879
Title
Selective resonant extraction from the Fermilab Main Injector using electron lens
Author
Shiltsev, V. ; Marriner, J.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume
2
fYear
2001
fDate
6/23/1905 12:00:00 AM
Firstpage
1468
Abstract
We propose to use an electron lens for slow extraction of proton bunches from the Fermilab Main Injector. A negatively charged electron beam colliding with protons causes positive tune shift proportional to the electron current. If the resulting tune satisfies the resonance condition, protons move to larger betatron amplitudes as in conventional slow extraction systems. Time variation of the electron current allows slow extraction from particular batches or even slow extraction from a single bunch
Keywords
electron accelerators; magnetic lenses; particle beam extraction; particle beam injection; storage rings; Fermilab Main Injector; betatron amplitudes; electron lens; proton bunch; resonant extraction; tune; Acceleration; Bandwidth; Colliding beam devices; Electron beams; Lenses; Magnets; Particle beams; Production; Protons; Resonance;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Print_ISBN
0-7803-7191-7
Type
conf
DOI
10.1109/PAC.2001.986716
Filename
986716
Link To Document