• DocumentCode
    3583924
  • Title

    Hydrostatic level system for slow ground motion studies at Fermilab and SLAC

  • Author

    Seryi, A. ; Ruland, R. ; Baklakov, B. ; Chupyra, A. ; Erokhin, A. ; Kondaurov, M. ; Medvedko, A. ; Parkhomchuk, V. ; Singatulin, Sh ; Shubin, E. ; Lach, J. ; Plant, D. ; Shiltsev, V.

  • Author_Institution
    SLAC, Stanford, CA, USA
  • Volume
    2
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    1479
  • Abstract
    A series of new ground motion studies using an upgraded hydrostatic level system are planned at Fermilab and SLAC in collaboration with BINP. To better characterize both the spatial and temporal characteristics of slow ground motion, these studies will use large number of probes and will also be performed in several geologically different locations. The hydrostatic level system used in ongoing measurements near Fermilab [1] suffers from uncertainty of temperature fluctuation effects. This paper presents improvements to be incorporated into the upgraded hydrostatic level system, present status, and the plan for experimental studies
  • Keywords
    hydrostatics; level measurement; linear colliders; probes; Fermilab; Hydrostatic Level Measurement System; SGMM System; SLAC; Slow Ground Motion Measurement System; air pressure sensors; ground motion; hydrostatic level sensors; hydrostatic level system; linear colliders; probes; temperature fluctuation; Collaboration; Colliding beam devices; Feedback; Geologic measurements; Geology; Land surface temperature; Level control; Motion measurement; Probes; Synthetic aperture sonar;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
  • Print_ISBN
    0-7803-7191-7
  • Type

    conf

  • DOI
    10.1109/PAC.2001.986720
  • Filename
    986720