DocumentCode
3586146
Title
An extended Park´s vector approach to detect broken bars faults in Induction Motor
Author
Bouslimani, S. ; Drid, S. ; Chrifi-alaoui, L. ; Bussy, P. ; Ouriagli, M. ; Delahoche, L.
Author_Institution
Dept. of Electr. Eng., Batna Univ., Batna, Algeria
fYear
2014
Firstpage
411
Lastpage
416
Abstract
In this article, we present a study based on the application of the new approach of the vectors of Park in the two axes ropers to the detection of the defects of bars in the three-phase induction machines. In order to simulate the behavior of the motor with defect, we propose the modeling of the diagram multi windings of the induction motor allowing apprehending his behavior in presence or absence of failures. The simulated results suggest that this method is effective and accurate and can be widely used in the induction motor fault diagnosis.
Keywords
bars; fault diagnosis; induction motors; machine windings; broken bars fault detection; diagram multiwindings; extended Park vector approach; fault diagnosis; induction motor; three-phase induction machines; Transforms; Condition Monitoring; Fault Diagnosis; Induction Motor; Park Vector Approach (PVA);
fLanguage
English
Publisher
ieee
Conference_Titel
Sciences and Techniques of Automatic Control and Computer Engineering (STA), 2014 15th International Conference on
Type
conf
DOI
10.1109/STA.2014.7086754
Filename
7086754
Link To Document