In this article, we present a study based on the application of the new approach of the vectors of Park in the two axes ropers to the detection of the defects of bars in the three-phase induction machines. In order to simulate the behavior of the motor with defect, we propose the modeling of the diagram multi windings of the induction motor allowing apprehending his behavior in presence or absence of failures. The simulated results suggest that this method is effective and accurate and can be widely used in the induction motor fault diagnosis.
Keywords :
bars; fault diagnosis; induction motors; machine windings; broken bars fault detection; diagram multiwindings; extended Park vector approach; fault diagnosis; induction motor; three-phase induction machines; Transforms; Condition Monitoring; Fault Diagnosis; Induction Motor; Park Vector Approach (PVA);