• DocumentCode
    3588528
  • Title

    Real time digital pulse analyzer for ITER neutron diagnostics

  • Author

    Ivanova, Alina A. ; Amosov, Vladimir N. ; Skopintsev, Dmitry A. ; Khilchenko, Aleksandr D. ; Kvashnin, Andrey N. ; Zubarev, Peter V. ; Ivanenko, Svetlana V. ; Kotelnikov, Aleksandr I. ; Puryga, Ekaterina A.

  • Author_Institution
    Novosibirsk State Tech. Univ., Novosibirsk, Russia
  • fYear
    2014
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    This paper proposes the approach to development of real time digital pulse analyzer of diamond detector for ITER Vertical Neutron Camera. It consists in the hardware implementation of data pre-processing unit. This approach reduces requirements of communication channels bandwidth and requirements of computing performance. Analyzer hardware platform is ADC12500PXIe recorder (2 channels, 12-bit, 500 MHz, PXI Express). The article describes the architecture of digital signal processing unit.
  • Keywords
    digital signal processing chips; pulse analysers; real-time systems; ADC12500PXIe recorder; ITER neutron diagnostics; ITER vertical neutron camera; analyzer hardware platform; data preprocessing unit; diamond detector; digital signal processing unit; real time digital pulse analyzer; Catalogs; Diamonds; Digital signal processing; Field programmable gate arrays; Linux; Neutrons; Real-time systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Real Time Conference (RT), 2014 19th IEEE-NPSS
  • Print_ISBN
    978-1-4799-3658-8
  • Type

    conf

  • DOI
    10.1109/RTC.2014.7097485
  • Filename
    7097485