• DocumentCode
    3588564
  • Title

    New DAQ system for the CANDLES experiment

  • Author

    Suzuki, K. ; Ajimura, S. ; Nomachi, M. ; Ogawa, I. ; Yoshizawa, M.

  • Author_Institution
    Grad. Sch. of Sci., Osaka Univ., Toyonaka, Japan
  • fYear
    2014
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    New data acquisition system for the CANDLES III experiment was developed by using Space-Wire protocol and DAQ-Middleware system. This system realizes a flexible and multi path of flash ADC access, and a parallel data acquisition by 3 PCs which read each buffers of flash ADCs. The speed of data acquisition becomes more 2 times higher than the single PC acquisition. We also developed a dynamic online monitor system independent with DAQ-Middleware.
  • Keywords
    data acquisition; middleware; CANDLES III experiment; DAQ middleware system; Space-Wire protocol; data acquisition system; dynamic online monitor system; flash ADC access; parallel data acquisition; Backplanes; Data acquisition; Impurities; Liquid crystals; Middleware; Monitoring; Servers; DAQ-Middleware; SpaceWire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Real Time Conference (RT), 2014 19th IEEE-NPSS
  • Print_ISBN
    978-1-4799-3658-8
  • Type

    conf

  • DOI
    10.1109/RTC.2014.7097521
  • Filename
    7097521