DocumentCode :
3588602
Title :
The use of USB 3.0 for fast data transfer in a PET detector
Author :
Wustner, P. ; Erven, A. ; Jokhovets, L. ; Kemmerling, G. ; Noldgen, H. ; Ramm, M. ; Streun, M. ; van Waasen, S.
Author_Institution :
Central Inst. for Eng., Electron. & Analytics, Forschungszentrum Julich, Julich, Germany
fYear :
2014
Firstpage :
1
Lastpage :
2
Abstract :
The Research Centre Juelich is developing a PET detector for plant phenotyping together with Philips Digital Photon Counting, Aachen. The scientific goal is to study the carbon transport in plants. To detect the photon pairs we use a ring of digital photon counters recently developed by Philips. For the prototype we decided to use a Xilinx Kintex evaluation board for data concentration and processing of the coincidences. It is assumed that the necessary data rate from the FPGA to the acquisition computer is about 300 MByte/s. As data link a 10-gigabit Ethernet link would be preferred, but the evaluation board contains a USB 3.0 interface already, therefore we chose to use this one in order to reduce the development costs.
Keywords :
biochemistry; biological techniques; botany; carbon; data acquisition; photodetectors; photomultipliers; positron emission tomography; 10-gigabit Ethernet link; C; PET detector; Philips Digital Photon Counting; USB 3.0; Universal Serial Bus; Xilinx Kintex evaluation board; acquisition computer; data concentration; data processing; digital photon counters; fast data transfer; photon pair detection; plant carbon transport; plant phenotyping; positron emission tomography; Communication cables; Computers; Detectors; Field programmable gate arrays; Photonics; Positron emission tomography; Universal Serial Bus;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Real Time Conference (RT), 2014 19th IEEE-NPSS
Print_ISBN :
978-1-4799-3658-8
Type :
conf
DOI :
10.1109/RTC.2014.7097559
Filename :
7097559