A study of bidirectional active and reactive power exchange and of the harmonic distortion in GTO thyristors rectifiers
Author
Nonnon, P. ; Escallier, D. ; Pouliquen, J.L. ; Saadate, Shahrokh ; Le Doeuff, R.
Author_Institution
Groupe de Recherche en Electrotech. et Electron. de Nancy, France
fYear
1990
Firstpage
317
Lastpage
321
Abstract
The high power AC-DC thyristor converters highly disturb the AC supply source. They necessarily consume reactive power and their power factor becomes poorer as the DC output voltage decreases. Furthermore they generate a big amount of current harmonics on the AC line. This harmonic disturbance is all the more important as the line short circuit power has a small value. The usual efficient solution is the use of costly and bulky harmonic filters or reactive power compensator. The authors propose a force-commutated converter structure in order to solve these problems. This set-up allows an independent control of active and reactive power exchange between AC line and DC load, as well as the control of harmonic distortion of AC variables. They consider the operating principle of the converter and discuss the results of numerical simulation. They compare this converter with a conventional converter
Keywords
harmonics; power convertors; power factor; reactive power; rectifying circuits; thyristor applications; AC line; DC load; GTO thyristors rectifiers; bidirectional active power exchange; force-commutated converter; harmonic distortion; high power AC-DC thyristor converters; numerical simulation; power factor; reactive power exchange;
fLanguage
English
Publisher
iet
Conference_Titel
Power Electronics and Variable-Speed Drives, 1991., Fourth International Conference on
Type
conf
Filename
114661
Link To Document