DocumentCode
3594097
Title
Bench measurements of low frequency transverse impedance
Author
Mostacci, A. ; Caspers, Fritz ; Iriso, U.
Author_Institution
Rome Univ., Italy
Volume
3
fYear
2003
Firstpage
1801
Abstract
For frequencies below 10 MHz the classical two wire transmission line method is subject to difficulties in sensitivity and measurement uncertainties. Thus for evaluation of the low frequency transverse impedance properties of the LHC dump kicker a modified version of the two wire transmission line has been used. It consists, in the present case, of a 10 turn loop of approximately 1 meter length and 2 cm width. The change of input impedance of the loop is measured as a function of the surroundings and by using a proper reference (metallic beam pipe) these changes are converted into a meaningful transverse beam coupling impedance. Measurements of several calibration objects have shown close agreement with theoretical results.
Keywords
particle beam diagnostics; storage rings; LHC dump kicker; Large Hadron Collider; classical two wire transmission line method; low frequency transverse impedance; metallic beam pipe; transverse beam coupling impedance; Electrical resistance measurement; Frequency measurement; Impedance measurement; Large Hadron Collider; Magnetic field measurement; Optical coupling; Transmission line measurements; Transmission line theory; Wavelength measurement; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
ISSN
1063-3928
Print_ISBN
0-7803-7738-9
Type
conf
DOI
10.1109/PAC.2003.1288675
Filename
1288675