• DocumentCode
    3597881
  • Title

    Experimental study of the voltage recovery characteristics of spark gap switch with different gases

  • Author

    Yin, Y. ; Liu, J.L. ; Zhong, H.H. ; Feng, J.H.

  • Author_Institution
    College of optoelectric Science and Engineering, National University of Defense Technology, 410073 Changsha, China
  • Volume
    1
  • fYear
    2007
  • Firstpage
    459
  • Lastpage
    463
  • Abstract
    This study uses a two-pulse method to determine the insulation recovery times of gas spark gap switch with different gas types applied in high power accelerator with water dielectric pulse forming line. Under the breakdown voltage of 450kV (the vacuum diode voltage is about 200kV), current 30kA, recovery characteristics of H2, N2, SF6 were studied. The recovery percentages of gas breakdown voltage and vacuum diode voltage were given. The results show that hydrogen has the best recovery characteristic. At a pulse interval of 8.8ms, recovery percentages of both gas breakdown voltage and vacuum diode voltage exceed 95%; for SF6, N2 with the interval of 25ms and 50ms, 90% voltage recovery percentages are obtained. The experiments also prove that the repetitive rate of high power accelerator with pulse forming line is mainly restricted by the gas switch repetitive rate; recovery percentages of the vacuum diode voltage and gas switch breakdown voltage are consistent; hydrogen switch can be employed for high repetitive rate high power accelerator with pulse forming line.
  • Keywords
    Breakdown voltage; Dielectrics and electrical insulation; Diodes; Gas insulation; Gases; Hydrogen; Sparks; Sulfur hexafluoride; Switches; Vacuum breakdown;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2007 16th IEEE International
  • Print_ISBN
    978-1-4244-0913-6
  • Electronic_ISBN
    978-1-4244-0914-3
  • Type

    conf

  • DOI
    10.1109/PPPS.2007.4651881
  • Filename
    4651881