• DocumentCode
    3598078
  • Title

    Large room temperature single crystal CdZnTe detectors

  • Author

    Trower, W.P.

  • Author_Institution
    World Phys. Technol., Blacksburg, VA, USA
  • fYear
    1997
  • Firstpage
    565
  • Abstract
    Large room temperature X-ray and γ-ray detectors with energy resolution comparable to cooled Ge detectors are needed for medical imaging, X-ray defectometry, dosimetry, metallurgical processing, ore assaying, oil well logging, and so on. We have produced Cd1-xZnxTe poly-crystals with diameters up to 50 mm, thicknesses up to 10 mm, and weights up to 80 g by a modified vapor phase growth technology. Thus we are establishing an attractive alternative to the high pressure Bridgman technique from which all commercial detectors are now made. We believe that our mVPG technology can be optimized to produce detector quality single CZT crystals of up to ~1,000 cm3 from which we can construct commercial X- and γ-ray detectors
  • Keywords
    X-ray detection; gamma-ray detection; semiconductor counters; vapour phase epitaxial growth; γ-ray detectors; 293 K; 50 mm; 80 g; CdZnTe; CdZnTe detectors; X-ray defectometry; X-ray detectors; dosimetry; energy resolution; medical imaging; modified vapor phase growth; room temperature; single crystal; Biomedical imaging; Dosimetry; Energy resolution; Gamma ray detection; Gamma ray detectors; Petroleum; Temperature; X-ray detection; X-ray detectors; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1997. IEEE
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-4258-5
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1997.672646
  • Filename
    672646