Title :
Commissioning results of the narrow-band beam position monitor system upgrade in the APS storage ring
Author :
Singh, O. ; Doose, C. ; Carwardine, J. ; Decker, G. ; Lenkszus, F. ; Merl, R.
Author_Institution :
Adv. Photon Source, Argonne Nat. Lab., IL, USA
fDate :
6/21/1905 12:00:00 AM
Abstract :
When using a low emittance storage ring as a high brightness synchrotron radiation source, it is critical to maintain a very high degree of orbit stability, both for the short term and for the duration of an operational fill. A fill-to-fill reproducibility is an additional important requirement. Recent developments in orbit correction algorithms have provided tools that are capable of achieving a high degree of orbit stability. However, the performance of these feedback systems can be severely limited if there are errors in the beam position monitors (BPMs). The present orbit measurement and correction system at the APS storage ring utilizes 360 broadband-type BPMs that provide turn-by-turn diagnostics and an ultra-stable orbit: <1.8 micron rms vertically and 4.5 microns rms horizontally in a frequency band of 0.017 to 30 Hz. The effects of beam intensity and bunch pattern dependency on these BPMs have been significantly reduced by employing “offset compensation” correction. Recently, 40 narrow-band switching-type BPMs have been installed in the APS storage ring, two in each of 20 operational insertion device straight sections, bringing the total number of beam position monitors to 400. The use of narrow-band BPM electronics is expected to reduce sensitivity to beam intensity, bunch pattern dependence, and long-term drift. These beam position monitors are used for orbit correction/feedback and machine protection interlocks for the insertion device beamlines. The commissioning results and overall performance for orbit stability are provided
Keywords :
electron accelerators; particle beam diagnostics; storage rings; APS storage ring; beam intensity; beam position monitors; broadband-type BPMs; bunch pattern dependence; bunch pattern dependency; feedback systems; fill-to-fill reproducibility; high brightness synchrotron radiation source; long-term drift; low emittance storage ring; machine protection interlocks; narrow-band beam position monitor system upgrade; narrow-band switching-type BPMs; offset compensation; operational insertion device straight sections; orbit correction algorithms; orbit stability; turn-by-turn diagnostics; ultra-stable orbit; Brightness; Extraterrestrial measurements; Feedback; Frequency measurement; Monitoring; Narrowband; Reproducibility of results; Stability; Storage rings; Synchrotron radiation;
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Print_ISBN :
0-7803-5573-3
DOI :
10.1109/PAC.1999.794383