• DocumentCode
    3600296
  • Title

    The Design of Wide Input Range and High-Precision Frequency Meter Based on FPGA

  • Author

    Li Jianjun ; Ma Xihong

  • Author_Institution
    Nat. Key Lab. For Electron. Meas. Technol., North Univ. of China, Taiyuan, China
  • fYear
    2010
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    The traditional frequency measurement using discrete devices, accuracy is low, and the restrictions on the intensity of input signal leading to the versatility of frequency counter is limited. According to the principle of equal precision, use FPGA to design equal precision, while use of FPGA and programmablf amplifier to amplify the measured signal automatically to achieve a wide range of frequency meter input and high-precision measurements.
  • Keywords
    amplifiers; field programmable gate arrays; frequency measurement; frequency meters; FPGA; frequency measurement; high-precision frequency meter; programmable amplifier; wide input range meter; Accuracy; Field programmable gate arrays; Measurement uncertainty; Radiation detectors; Time frequency analysis; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    E-Product E-Service and E-Entertainment (ICEEE), 2010 International Conference on
  • Print_ISBN
    978-1-4244-7159-1
  • Type

    conf

  • DOI
    10.1109/ICEEE.2010.5661351
  • Filename
    5661351