DocumentCode :
3602248
Title :
Comparison of Acoustic Radiation Force Impulse Imaging Derived Carotid Plaque Stiffness With Spatially Registered MRI Determined Composition
Author :
Doherty, Joshua R. ; Dahl, Jeremy J. ; Kranz, Peter G. ; El Husseini, Nada ; Hing-Chiu Chang ; Nan-kuei Chen ; Allen, Jason D. ; Ham, Katherine L. ; Trahey, Gregg E.
Author_Institution :
Dept. of Biomed. Eng., Duke Univ., Durham, NC, USA
Volume :
34
Issue :
11
fYear :
2015
Firstpage :
2354
Lastpage :
2365
Abstract :
Measurements of plaque stiffness may provide important prognostic and diagnostic information to help clinicians distinguish vulnerable plaques containing soft lipid pools from more stable, stiffer plaques. In this preliminary study, we compare in vivo ultrasonic Acoustic Radiation Force Impulse (ARFI) imaging derived measures of carotid plaque stiffness with composition determined by spatially registered Magnetic Resonance Imaging (MRI) in five human subjects with stenosis >50%. Ultrasound imaging was implemented on a commercial diagnostic scanner with custom pulse sequences to collect spatially registered 2D longitudinal B-mode and ARFI images. A standardized, multi-contrast weighted MRI sequence was used to obtain 3D Time of Flight (TOF), T1 weighted (T1W), T2 weighted (T2W), and Proton Density Weighted (PDW) transverse image stacks of volumetric data. The MRI data was segmented to identify lipid, calcium, and normal loose matrix components using commercially available software. 3D MRI segmented plaque models were rendered and spatially registered with 2D B-mode images to create fused ultrasound and MRI volumetric images for each subject. ARFI imaging displacements in regions of interest (ROIs) derived from MRI segmented contours of varying composition were compared. Regions of calcium and normal loose matrix components identified by MRI presented as homogeneously stiff regions of similarly low (typically ≈ 1 μm) displacement in ARFI imaging. MRI identified lipid pools > 2 mm2, found in three out of five subjects, presented as softer regions of increased displacement that were on average 1.8 times greater than the displacements in adjacent regions of loose matrix components in spatially registered ARFI images. This work provides early evidence supporting the use of ARFI imaging to noninvasively identify lipid regions in carotid artery plaques in vivo that are believed to increase the propensity of a plaque to rupture. Additionally, - he results provide early training data for future studies and aid in the interpretation and possible clinical utility of ARFI imaging for identifying the elusive vulnerable plaque.
Keywords :
biomedical MRI; biomedical ultrasonics; brain; image registration; image segmentation; image sequences; medical image processing; 3D MRI segmented plaque models; 3D time of flight transverse image; T1 weighted transverse image; T2 weighted transverse image; carotid plaque stiffness; in vivo ultrasonic acoustic radiation force impulse imaging; magnetic resonance imaging; proton density weighted transverse image; spatially registered 2D longitudinal ARFI images; spatially registered 2D longitudinal B-mode images; spatially registered MRI determined composition; ultrasound imaging; Image segmentation; Lipidomics; Magnetic resonance imaging; Solid modeling; Three-dimensional displays; Ultrasonic imaging; MRI; multi-modality fusion; ultrasound; vessels;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2015.2432797
Filename :
7106525
Link To Document :
بازگشت