DocumentCode :
3602373
Title :
A 3-D Level Set Method for Microwave Breast Imaging
Author :
Colgan, Timothy J. ; Hagness, Susan C. ; Van Veen, Barry D.
Author_Institution :
Dept. of Electr. & Comput. Eng., Univ. of Wisconsin-Madison, Madison, WI, USA
Volume :
62
Issue :
10
fYear :
2015
Firstpage :
2526
Lastpage :
2534
Abstract :
Objective: Conventional inverse-scattering algorithms for microwave breast imaging result in moderate resolution images with blurred boundaries between tissues. Recent 2-D numerical microwave imaging studies demonstrate that the use of a level set method preserves dielectric boundaries, resulting in a more accurate, higher resolution reconstruction of the dielectric properties distribution. Previously proposed level set algorithms are computationally expensive, and thus, impractical in 3-D. In this paper, we present a computationally tractable 3-D microwave imaging algorithm based on level sets. Methods: We reduce the computational cost of the level set method using a Jacobian matrix, rather than an adjoint method, to calculate Frechet derivatives. We demonstrate the feasibility of 3-D imaging using simulated array measurements from 3-D numerical breast phantoms. We evaluate performance by comparing full 3-D reconstructions to those from a conventional microwave imaging technique. We also quantitatively assess the efficacy of our algorithm in evaluating breast density. Results: Our reconstructions of 3-D numerical breast phantoms improve upon those of a conventional microwave imaging technique. The density estimates from our level set algorithm are more accurate than those of the conventional microwave imaging, and the accuracy is greater than that reported for mammographic density estimation. Conclusion: Our level set method leads to a feasible level of computational complexity for full 3-D imaging, and reconstructs the heterogeneous dielectric properties distribution of the breast more accurately than conventional microwave imaging methods. Significance: 3-D microwave breast imaging using a level set method is a promising low-cost, nonionizing alternative to current breast imaging techniques.
Keywords :
Jacobian matrices; bioelectric phenomena; biological tissues; computational complexity; image reconstruction; mammography; medical image processing; microwave imaging; phantoms; 2-D numerical microwave imaging; 3-D level set method; 3-D microwave breast imaging; 3-D microwave imaging algorithm; 3-D numerical breast phantoms; Frechet derivatives; Jacobian matrix; adjoint method; breast density; computational complexity; conventional inverse-scattering algorithms; conventional microwave imaging technique; full 3-D reconstructions; heterogeneous dielectric property distribution; higher resolution reconstruction; mammographic density estimation; simulated array measurements; tissues; Breast; Dielectrics; Image reconstruction; Level set; Microwave imaging; Permittivity; Breast density; breast density; level set method; microwave imaging;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2015.2435735
Filename :
7110543
Link To Document :
بازگشت