• DocumentCode
    3602538
  • Title

    Study on the Magnetization Dynamics of Ni–Fe Dot Arrays Estimated by the CPW-FMR Measurement Method

  • Author

    Endo, Yasushi ; Shimada, Yutaka ; Yamaguchi, Masahiro

  • Author_Institution
    Dept. of Electr. Eng., Tohoku Univ., Sendai, Japan
  • Volume
    51
  • Issue
    11
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper describes the magnetization dynamics of Ni-Fe dot array estimated by the ferromagnetic measurement with the coplanar waveguide. The magnetic configuration of the dot changes from a multi-domain to a closure domain as the dot size decreases. The switching field at which a single domain is formed increases with the dot size reduction, which may be attributed to the enhanced magnetostatic energy. On the other hand, the damping constant decreases monotonically from 0.029 to 0.012 for the major axis length <;1 μm, and their values are higher than that of the Ni-Fe film (α = 0.009). The reason for these differences is that the demagnetization field distribution near the dot edge becomes inhomogeneous with the dot size reduction. On the basis of these results, it is revealed that the extrinsic factor, such as the inhomogeneous demagnetization field distribution, strongly influences on the damping constant. These results also suggest that the correlation with the magnetic configuration of the dot is one of the most important to understand the magnetization dynamics in submicrometer-sized magnets in detail.
  • Keywords
    coplanar waveguides; damping; demagnetisation; ferromagnetic resonance; iron; magnetic thin films; magnetisation; metallic thin films; nickel; CPW-FMR measurement method; Ni-Fe; Ni-Fe dot arrays; Ni-Fe film; coplanar waveguide; damping constant; dot edge; enhanced magnetostatic energy; ferromagnetic measurement; inhomogeneous demagnetization field distribution; magnetic configuration; magnetization dynamics; submicrometer-sized magnets; switching field; Damping; Magnetic domains; Magnetic field measurement; Magnetic resonance; Magnetomechanical effects; Magnetostatics; CPW-FMR measurement; Coplanar waveguide ferromagnetic resonance (CPW-FMR) measurement; Ni-Fe dot array; Ni???Fe dot array; damping constant; magnetic field sweeping (MFS)-magnetic force microscope; magnetic field sweeping-magnetic force microscope;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2015.2434400
  • Filename
    7113840