• DocumentCode
    3608469
  • Title

    Comparison Between Simulations Using the PHITS Code and Activated Material Analysis

  • Author

    Sukegawa, Atsuhiko M. ; Okuno, Koichi

  • Author_Institution
    Japan Atomic Energy Agency, Naka, Japan
  • Volume
    43
  • Issue
    11
  • fYear
    2015
  • Firstpage
    3916
  • Lastpage
    3920
  • Abstract
    In this study, a comparison between simulations using the Particle and Heavy Ion Transport code System (PHITS) code and activated material analysis of JT-60U have been performed. Neutron transport has been simulated using the Monte Carlo method PHITS to determine the neutron fluency at the irradiation position. The activated analysis has been complemented by the foil-activation technique. The preliminary accuracy assessment of these PHITS simulations has been confirmed by comparing the reaction rates of gold, cobalt, and nickel foil activation. The simulation results by PHITS consistent with the measured reaction rate of each foil near the device.
  • Keywords
    Monte Carlo methods; Tokamak devices; cobalt; gold; nickel; plasma chemistry; plasma simulation; plasma toroidal confinement; plasma transport processes; Au; Co; JT-60U material analysis; Monte Carlo method PHITS; Ni; cobalt foil activation; gold foil activation; neutron fluency determination; neutron transport simulations; nickel foil activation; particle and heavy ion transport code system; reaction rates; Analytical models; Atomic measurements; Monte Carlo methods; Neutrons; Plasmas; Safety; Solid modeling; DCHAIN-SP 2001; JT-60; Particle and Heavy Ion Transport code System (PHITS); foil-activation technique: induced-activity; radiation safety; tokamak fusion device; tokamak fusion device.;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2015.2478902
  • Filename
    7299669