    Design of Automatic Reclosing scheme in distribution feeders

  • Author

    Vasco, J. ; Aguila, A.

  • Author_Institution
    Univ. Politec. Salesiana, Quito, Ecuador
  • Volume
    13
  • Issue
    8
  • fYear
    2015
  • Firstpage
    2587
  • Lastpage
    2593
  • Abstract
    This paper aims to serve as a document for the implementation of the system of reconnection in distribution feeders. Has become necessary in which to gather information about the failures raised in the specified evaluation period. The result would be to identify the number of failures that were cleared by the operation of the instantaneous overcurrent function in both phases and neutral primary feeders considered for undergraduate work. This could work on the design, to establish the number of reconnections that could have the feeder, the reconnection time it should have, that direct the type of equipment breakdown and the largest type of load served relationship. Part of the design is the intervention of control and protection circuits in each of the primary, in circuits opening, closing and locking. These must have a relationship with reclosing relay for the operation of reclosing. In different substations are installed relays IED, in this case it is necessary to intervene in the operating logic also enable reclosing function. In addition to link protection function whit reclosing relay. As in a SCADA system is important to re-build the communication parameters IEC 618 050 to have alarms on consoles operation control center, it is necessary to reconfigure the protocol and update the gateway, which no remote control operation is affected and work on par with reconnection function enabled.
  • Keywords
    IEC standards; SCADA systems; distribution networks; overcurrent protection; protocols; substations; IEC 618 050 communication parameters; SCADA system; automatic reclosing scheme; consoles operation control center; control circuits; distribution feeders; equipment breakdown; installed relays IED; instantaneous overcurrent function; link protection function; load served relationship; neutral primary feeders; protection circuits; protocol reconfiguration; reclosing relay; reconnection system; substations; undergraduate work; Electric breakdown; IEC Standards; IEEE Standards; Monitoring; Relays; Silicon; Substations; IEC 61850; Protecction of distribution feeders; comunication; control scheme; fault in feeders;
  • fLanguage
    English
  • Journal_Title
    Latin America Transactions, IEEE (Revista IEEE America Latina)
  • Publisher
    ieee
  • ISSN
    1548-0992
  • Type

    jour

  • DOI
    10.1109/TLA.2015.7332136
  • Filename
    7332136