Abstract
It is known that real-time power quality monitoring is usually rather difficult to achieve due to the requirement of expensive equipments and necessary of more signals to be captured. To solve this problem, this study combines fractional order Sprott chaos synchronisation system with extension theory to detect power signal disturbance including voltage swell, sag, interruption, and harmonics for real-time power quality monitoring. The use of fractional order chaotic systems can significantly improve the situations of misjudgement due to the dynamic error is too large by using general integer order chaotic systems. Otherwise, the three-dimensional (3D) Sprott error dynamics can be reduced to 2D error system. It will become easier and cheaper to implement this scheme in the portable device. The results of numerical simulation show that the detection accuracy rate is 100% and it is better than the methods in previous studies. It should be able to get a very high diagnostic accuracy if this method can be applied to the actual power system.
Keywords
chaos; numerical analysis; power supply quality; power system faults; power system measurement; synchronisation; dynamic error; fractional order Sprott chaos synchronisation; integer order chaotic systems; numerical simulation; power signal disturbance; real time extension power quality detection; real-time power quality monitoring; three-dimensional Sprott error dynamics; voltage interruption; voltage sag; voltage swell;
fLanguage
English
Journal_Title
Generation, Transmission Distribution, IET
Publisher
iet
ISSN
1751-8687
Type
jour
DOI
10.1049/iet-gtd.2015.0500
Filename
7337582
Link To Document