  • Abstract
    We present the challenges of using new medical proton therapy cyclotrons for SEE tests in the 200 MeV regime. Solutions are discussed to utilize these facilities as a replacement for the Indiana University Cyclotron Facility. Part data response to conventional scattered proton beams are compared to newer scanning beam configurations. A common dosimetry system for independent determination of fluence and beam uniformity is presented.
  • Keywords
    cyclotrons; dosimetry; radiation therapy; Indiana University Cyclotron Facility; U.S. medical proton facilities application; U.S. medical proton facilities evaluation; beam uniformity; dosimetry system; medical proton therapy cyclotron; scanning beam configuration; scattered proton beam; single event effects test; Cyclotrons; Dosimetry; Particle beams; Radiation hardening (electronics); Dosimetry; proton beams; radiation hardness assurance; single event effects;