    Myocardial strain imaging with tagged MRI

  • Author

    N.J. Tustison;D. Abendschein;V.G. Davila-Roman;A.A. Amini

  • Author_Institution
    CVIA Lab., Washington Univ., St. Louis, MO, USA
  • Volume
    1
  • fYear
    2002
  • fDate
    6/24/1905 12:00:00 AM
  • Firstpage
    723
  • Abstract
    A 4-D B-spline model has been created to accurately capture the dynamic motion of the heart from tagged magnetic resonance imaging (MRI) enabling displacement field reconstruction of myocardial deformation. The 4-D model is allowed to deform based on the location of the tag lines for all frames within the constraints of the model´s spatio-temporal internal energy. From a displacement field, the corresponding long and short axis Lagrangian strain maps are produced. Motion fields from simulated data produced by a cardiac motion simulator are used to create corresponding strain images. In addition, strain images produced from porcine data with posterolateral myocardial infarction are illustrated.
  • Keywords
    "Myocardium","Capacitive sensors","Magnetic resonance imaging","Spline","Deformable models","Surface fitting","Solid modeling","Heart","Image reconstruction","Magnetic field induced strain"
  • Publisher
    ieee
  • Conference_Titel
    Pattern Recognition, 2002. Proceedings. 16th International Conference on
  • ISSN
    1051-4651
  • Print_ISBN
    0-7695-1695-X
  • Type

    conf

  • DOI
    10.1109/ICPR.2002.1044860
  • Filename
    1044860