DocumentCode
3620447
Title
Analysis of forward problem for elliptical geometry in EIT by using analytical and finite element methods
Author
K.E. Akdogan;A. Yilmaz;B. Saka
Author_Institution
Dept. of Electr. & Electron. Eng., Hacettepe Univ., Ankara, Turkey
Volume
1
fYear
2003
fDate
6/25/1905 12:00:00 AM
Firstpage
372
Abstract
Electrical impedance tomography (EIT) is a technique that computes the cross-sectional impedance distribution within the body. It is reported that the image reconstruction is distorted considerably when the boundary shape is considered to be more elliptical than circular in thorax model. In this paper, the forward problem of EIT is analyzed by analytical and verified by finite element model (FEM) for both circular and elliptic frames
Keywords
"Geometry","Finite element methods","Tomography","Electrodes","Mathematical model","Impedance","Solid modeling","Image reconstruction","Thorax","MATLAB"