DocumentCode
3621414
Title
Low microbubble concentrations signal enhancement varying echograph electrical power
Author
S. Casciaro;A. Distante;R.P. Errico;C. Demitri;F. Conversano;G. Palma;E. Casciaro
Volume
4
fYear
2005
fDate
6/27/1905 12:00:00 AM
Firstpage
2011
Lastpage
2013
Abstract
This work has the aim to assess the influence of the Echograph Electrical Power (EEP) on the ultrasound contrast agent (UCA) behavior and the effect of UCA concentration on backscatter enhancement. In several studies there has been the tendency to use high UCA concentrations and high EEP, but this could limit the safety of the microbubbles. Here we show an investigation able to determine the effect on the backscatter intensity varying EEP and UCA concentrations. A new phospolipidic UCA and the last technological innovations in the field of signal processing and radiofrequency (RF) spectrum analysis were used in this study. Eighteen different saline-diluted UCA solutions were pumped into the vessel cavities of a new tissue-mimicking phantom and insonified at constant frequency varying EEP. The acquired RF data were digitally stored and off-line processed by algorithms ad hoc developed by means of a new software research package. The obtained results show that UCA backscatter can be considered independent by UCA concentration at high dilutions, while it is clearly influenced by incident acoustic pressure values in the whole tested dilution range.
Keywords
"Imaging phantoms","Ultrasonic imaging","Backscatter","Radio frequency","Signal processing algorithms","Stability","Liver","Nonlinear acoustics","Probes","Physiology"
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2005 IEEE
ISSN
1051-0117
Print_ISBN
0-7803-9382-1
Type
conf
DOI
10.1109/ULTSYM.2005.1603272
Filename
1603272
Link To Document