DocumentCode
3622204
Title
Continuous Wavelet Transform for Bearing Damage Detection in Electric Motors
Author
E. Ayaz;A. Ozturk;S. Seker
Author_Institution
Electrical Engineering Department, İ
fYear
2006
fDate
6/28/1905 12:00:00 AM
Firstpage
1130
Lastpage
1133
Abstract
The purpose of this paper is to extract features from vibration signals measured from induction motors subjected to accelerated bearing fluting aging. The signals taken from accelerometers placed near to process end bearing were first combined using simple sensor fusion method and then spectral analysis and time-scale analysis were performed. Fused vibration signals were decomposed into several scales using continuous wavelet transform analysis and selected scales was further investigated to get detailed information relating to bearing damage features. And also the advantage of the continuous wavelet transform over short time Fourier transform was emphasized in terms of getting the bearing damage between 2-4 kHz
Keywords
"Continuous wavelet transforms","Wavelet transforms","Electric motors","Vibration measurement","Signal analysis","Fourier transforms","Feature extraction","Induction motors","Accelerated aging","Signal processing"
Publisher
ieee
Conference_Titel
Electrotechnical Conference, 2006. MELECON 2006. IEEE Mediterranean
ISSN
2158-8473
Print_ISBN
1-4244-0087-2
Electronic_ISBN
2158-8481
Type
conf
DOI
10.1109/MELCON.2006.1653299
Filename
1653299
Link To Document