DocumentCode
3629291
Title
Analysis of CR dose reduction in pediatric patients, based on computer-simulated noise addition
Author
B. Juste;J.I. Villaescusa;R. Tortosa;R. Miro;G. Verdu
Author_Institution
Chemical and Nuclear Engineering Department at the Polytechnic University of Valencia, Cam? de Vera s/n 46022 Spain
fYear
2008
Firstpage
2697
Lastpage
2700
Abstract
This paper validates a technique to add statistical noise to a Computed Radiography (CR) in order to simulate accurately how the same image would appear if taken at a reduced tube current. To that, a noise addition software has been developed to create lower dose CR using existing pediatric radiographies based on the selection of lower X-ray tube current. The effect of different milliAmpere-seconds (mAs) setting on image quality has been evaluated using the CDMAM 3.4 phantom and the obtained results show good agreements between the simulated and real images in terms of noise measurement. The new CR images allow medical researchers to study how lower dose affects the patient diagnosis.
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
ISSN
1094-687X
Print_ISBN
978-1-4244-1814-5
Electronic_ISBN
1558-4615
Type
conf
DOI
10.1109/IEMBS.2008.4649758
Filename
4649758
Link To Document