• DocumentCode
    3629535
  • Title

    Capacitive coupling clamp

  • Author

    Slavko Radman;Iva Bacic;Kresimir Malaric

  • Author_Institution
    Dept. of Wireless Communication, Faculty of Electrical Engineering and Computing, Unska 3, 10 000 Zagreb, Croatia
  • fYear
    2008
  • Firstpage
    75
  • Lastpage
    79
  • Abstract
    This paper reports on a great area of electromagnetic compatibility. Special attention is given to measurement of electromagnetic interference established via the cable. A capacitive coupling clamp that conforms to requirements of ISO 64000-4-4 is built for measuring the resistance of three different cables (a twisted pair, RG - 58A/U and RG - 213/U) to external sources of continuous electromagnetic waves. The result is comparison of resistance to external interference of named cables.