DocumentCode :
3630241
Title :
Preliminary tests of semi-insulating GaAs radiation detectors coupled to the multichannel ASIC DX64 readout chip
Author :
B. Zat´ko;F. Dubecky;P. Scepko;P. Grybos;J. Mudron
Author_Institution :
Institute of Electrical Engineering, Slovak Academy of Sciences, D?bravsk? cesta 9, SK-841 04 Bratislava, Slovakia. e-mail: elekbzat@savba.sk
fYear :
2008
Firstpage :
339
Lastpage :
342
Abstract :
This work deals with the performance of semi-insulating GaAs-based detectors of ionizing radiation DC-coupled to the multichannel readout chip ASIC DX64. Fabricated detectors have circular Ti/Pt/Au Schottky blocking contact with four different diameters and full area AuGeNi eutectic alloy quasi-ohmic contact on the opposite site. The current-voltage characteristics and 241Am pulse-height spectra of the detectors were measured and evaluated. It is demonstrated that the system allows operation in single photon counting regime applicable in new generation "quantum" and digital X-ray imaging and foreseen energy separation so called "colour" imaging applications.
Keywords :
"Testing","Gallium arsenide","Radiation detectors","Application specific integrated circuits","Pulse measurements","Ionizing radiation","Gold alloys","Platinum alloys","Titanium alloys","Current-voltage characteristics"
Publisher :
ieee
Conference_Titel :
Advanced Semiconductor Devices and Microsystems, 2008. ASDAM 2008. International Conference on
Print_ISBN :
978-1-4244-2325-5
Type :
conf
DOI :
10.1109/ASDAM.2008.4743353
Filename :
4743353
Link To Document :
بازگشت