Title :
A comparative study of undoped NaI scintillators with different purity
Author :
M. Moszynski;W. Czarnacki;A. Syntfeld-Kazuch;A. Nassalski;T. Szczesniak;L. Swiderski;F. Kniest;A. Iltis
Author_Institution :
Soltan Institute for Nuclear Studies, PL 05-400 ?wierk-Otwock, Poland
Abstract :
The performance of undoped NaI crystal of a high purity of 7 N grade, developed by Saint-Gobain Crystals for a dark matter search, was studied at liquid nitrogen temperature using avalanche photodiode. The measured quantities covered the light output expressed in the electron-hole (e–h) pair number, non-proportionality characteristics, energy resolution and finally the intrinsic resolution of the studied crystals. In contrast to the previous study, the new crystals showed comparable non-proportionality curves to that known for NaI(Tl) at room temperature and a poor energy resolution of about 8% for 662 keV gamma rays from 137Cs source. The performed study highlights a role of undoped NaI crystals in a better understanding of limitations of energy resolution in scintillation detectors. A high sensitivity to traces of doping may help to find the way of a modification of non-proportionality of other scintillators by a selective doping or co-doping. A further study of slow components of the NaI light pulses and their influence on energy resolution may clear up its possible deterioration by defects in the crystal structures.
Keywords :
"Crystals","Energy resolution","Temperature","Gamma rays","Nitrogen","Avalanche photodiodes","Doping","Detectors","Impurities","Spectroscopy"
Conference_Titel :
Nuclear Science Symposium Conference Record, 2008. NSS ´08. IEEE
Print_ISBN :
978-1-4244-2714-7
DOI :
10.1109/NSSMIC.2008.4774602